Using the Web Mountain RUC-01 with the ESI Drapery Control System
Electronic Solutions, Inc, (ESI), is a manufacturer of an extremely powerful and flexible drapery control
system. They make controllers that control the motors to open, lower, or set blinds and drapes to any
position. There are two main pieces to their system of interest to us the actual motor controllers
themselves (RP or RQ series) and the interface devices (R2D7 or RQ Bridge). The interface devices
provide an RS-232 serial interface that we can use to interface to the RUC, and then the motor
controllers are connected to the interface device via cabling on what ESI calls the RP Bus, or the RQ Bus.
RP System
Let’s start with the ESI RP System. This is ESI’s original product offering, which is still being sold today.
The RP system is one direction only commands are issued from a controller either a manual
controller, or an intelligent controller such as the RUC-01. The commands are received by the motor
controllers and acted upon. The motor controllers have to be programmed and then calibrated to
match the blind or drape they are controlling. Commands would look like *1c01; or *1o02;.
Here is a drawing of how the RP System is connected to the RUC-01.
RUC-01R2D7
RS-
232
COM2
COM1
Other protocol for
Triggering, i.e., UPB
SYS1
MAIN
Motor Controller 1
RP60
Motor Controller 2
RP60
EYE EYEAUX AUX
MTR MTR
Blind / Drape Blind / Drape
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - Blind / Drape Blind / Drape

Using the Web Mountain RUC-01 with the ESI Drapery Control System Electronic Solutions, Inc, (ESI), is a manufacturer of an extremely powerful and f

Page 2

The command !WBT>00; indicates that the motor is moving and started from a fully open position. Let’s say that we want some lights controlled by

Page 3

Notice that you don’t need the leading ! or the trailing ;. The ESI command type takes care of this. Now, when you click on Add Trigger, the trigger

Page 4

And, the trigger listing will look like this: While this demo was done with UPB, you could just as easily perform these same functions using Zwave o

Page 5

Pick a COM port that will not commonly be used on your PC – we picked COM8 in this example. Use the drop down and select COM8. In the IP address fi

Page 6 - Blind / Drape

Now, click on the button in HW-VSP that says Create COM. You will see the status under VSP change to “Created” and Status under LAN change to Connect

Page 7

For more information, please contact Web Mountain Technologies at 303-627-1856 or [email protected].

Page 8

Now, the RUC-01 can be used to control the blinds by several methods (we call them Trigger Events):  Time of Day (including Sunset / Sunrise)  Upo

Page 9

Notice that we are using the Command type in the Send Command area as RAW. This means that the RUC will not take care of any characters for you, mos

Page 10

Get back to the Trigger Event screen. Here’s what the screen will look like to trigger on a UPB command of NID = 66, Link ID = 13 with a command of Ac

Page 11

for much finer detail and control of individual motor controllers. Motor controllers are addressed randomly at the factory with an address that looks

Page 12

RUC-01RQ BridgeRS-232COM2COM1Other protocol for Triggering, i.e., UPBRQBUSMotor Controller 1RQ60EYE AUXMTRRQBUSM50Q Enabled Blind / ShadeBlind / Drape

Page 13

2. Setup COM2 on the Device Configuration page for the ESI settings, namely 9600-8-N-1. 3. Now, go to the Trigger Events page and let’s add some tri

Page 14

And, we could do the same thing we did above with the RP command, use a UPB command or Zwave command to trigger sending the ESI RQ command. You might

Page 15

!000v?; Request addresses and version numbers of all RQ elements !000r? Request the position of all the RQ60 controllers (blinds are open, closed